System no..: PD410

CD leveling construction

Galvanized metal substructure at the same height for hanging plasterboard panels smooth, perforated or slotted.

Description and installation instructions

 

First, the U-connection profiles No. 5179 are dowelled to the walls all around at intervals of 500 mm. The CD Cross Profiles are clipped in place using inserted CD Cross Connectors.

 

The CD Cross Profiles No. 5118 are clipped into the CD Support Profiles, which are suspended at intervals of 1250 mm, at intervals of 500 mm using CD Safety Cross Connectors inserted into the CD Cross Profiles. The rail joints of the support rails No. 5120 are to be connected with the longitudinal connector No. 6079. Maximum hanger distance from the wall = 250mm

 

The gypsum plasterboards are screwed to the C ceiling profile grating with drywall screws.

 

There are three possibilities for suspension:

1. CD hanger with special tension spring no. 6038 and suspension wire with eyelet (125-2000 mm long).

2. CD nonius hanger No. 6018 and adjusting rod. Nonius hanger and adjustment rod must be connected by a safety clip or 2 safety clamps. Not self-locking clamps must be bent over. With this construction a rigid suspension is achieved, which can be adjusted exactly to 1 mm.

3. hangers and rail joints must be arranged offset. At the rail joint a hanger is to be arranged additionally

Specifications

Standard EN 13964/DIN 18168-2 & DIN EN 1364

Products

Products in this system

5120

Application area: suspended ceilings and wall facings.

5118

Application area: hanging ceilings and wall facings.

Protektor Noniusunterteil zur Befestigung von CD-Profilen für Decken-Unterkonstruktionen mit Noniusabhängung.

6018

For attaching CD profiles on ceiling sub-constructions with vernier suspensions.

6079

For connecting CD 60-27 profiles lengthwise.

6116

For connecting CD profiles on ceiling sub-constructions.

6201

Application area: ceiling substructures to create a connection between vernier shells and subdividers. Bend around fixing clip after installing.

6199