System no..: PD300

Corrosion protected ceiling substructure C3

For hanging various panelling materials in stress areas: DIN 18168-1, table 2, line 2 DIN EN 13964, Table 7 and 8 Class C

Description and installation instructions

  • First, the U-connection profile No. 58122 is doweled to the walls all around at intervals of approx. 500 mm.
  •  The CD support profiles No. 58102 are placed on top of the U-connection profile and then the hangers are attached. Maximum hanger distance from the wall 1/3 hanger distance, maximum support profile distance from the wall 1/3 of the permissible panel profile span.
  • To do this, the CD panel profiles No. 58102 are inserted into the U-connection profile and connected to the suspended CD support profiles using cross quick connectors No. 58104. The center distance of the 1st CD panel profile from the wall is specified in the mounting table according to the panel type and thickness (e.g. 500 mm for 12.5 mm GK panel).
  • Profile joints must be arranged offset using CD Connector No. 58103. In the case of CD support profiles, an additional hanger must be arranged at the profile joint.
  • Finally, the panelling plates are screwed on with drywall screws without pre-drilling and at right angles to the plate profiles. The screwing and subsequent filling must be done according to the installation guidelines of the panel manufacturers.

Specifications

Standard DIN EN ISO 12944-6 / DIN 55634

Products

Products in this system

58103

For laterally connecting CD 60-27 profiles with increased corrosion resistance requirements.

58102

Application area: hanging ceilings and wall facings with increased corrosion resistance requirements.

58104

For creating cross connections for CD profiles on hanging ceiling sub-constructions with increased corrosion resistance requirements.

58108

For attaching CD profiles on ceiling sub-constructions with vernier suspensions increased corrosion resistance.

58107

Application area: ceiling sub-constructions as a connection between vernier shells and subdividers, with increased corrosion resistance requirements. Please apply 2 pieces per connection.

58122

Application area: connection profile for hanging ceilings and wall facings with increased corrosion resistance requirements.

6248

For installing UW profiles with a drilling diameter of 6 mm. Max. mounting thickness of 12 mm. Not suitable for suspended ceilings!