System no..: PW810

Corrosion protected single stud wall C5-M

Wall system according to DIN 18183 + DIN 4103

General remarks

  •  Stiffening profiles, filler profiles for edges, junctions and terminations etc. as required.
  •  When planking the substructure with other cladding materials, e.g. gypsum fiber boards, special fire protection boards, chipboards, etc., the technical data and processing guidelines of the respective manufacturer must be observed! 

Specifications

Standard DIN 18183 + DIN 4103
Thickness 75, 100, 125
Permitted heights 3000–5000 mm
2750–4250 mm
Variants CW 50/75 CW 75/100 CW 100/125
Fire protection F-30-A/EI 30
Sound insulation RW,R 40–47

Products

Products in this system

58206

For connecting panelling materials for sheet metal thicknesses of up to 0.7 mm with double lead thread with increased corrosion resistance requirements.

58205

For connecting panelling materials for sheet metal thicknesses of up to 0.7 mm with double lead thread with increased corrosion resistance requirements.

59033

Application area: supporting bracket for walls/wall faces or for free-spanning ceilings with increased corrosion resistance requirements.

59030

Application area: supporting bracket for walls/wall faces or for free-spanning ceilings with increased corrosion resistance requirements.

59216

Application area: stand profile for walls/wall faces or support profile for free-spanning ceilings with increased corrosion resistance requirements. H cut-out at each end, continuously every 250 mm and subsequently every 500 mm.

59215

Application area: stand profile for walls/wall faces or support profile for free-spanning ceilings with increased corrosion resistance requirements. H cut-out at each end, continuously every 250 mm and subsequently every 500 mm.

59211

Application area: stand profile for walls/wall faces or support profile for free-spanning ceilings with increased corrosion resistance requirements. H cut-out at each end, continuously every 250 mm and subsequently every 500 mm.

59233

Application area: supporting bracket for walls/wall faces or for free-spanning ceilings with increased corrosion resistance requirements.

59230

Application area: supporting bracket for walls/wall faces or for free-spanning ceilings with increased corrosion resistance requirements.

59234

Application area: supporting bracket for walls/wall faces or for free-spanning ceilings with increased corrosion resistance requirements.

6194

Application area: connection sealing strips, self-gluing one side for ceiling constructions. Building material class B2.

6195

Application area: connection sealing strips, self-gluing one side for ceiling constructions. Building material class B2.

6196

Application area: connection sealing strips, self-gluing one side for ceiling constructions. Building material class B2.