System no..: PW800

Corrosion protected single stud wall C3

Wall system according to DIN 18183 + DIN 4103

General remarks

  • Stiffening profiles, filler profiles for edges, junctions and terminations etc. as required.
  •  When planking the substructure with other cladding materials, e.g. gypsum fiber boards, special fire protection boards, chipboards, etc., the technical data and processing guidelines of the respective manufacturer must be observed! 

Wall system 

Specifications

Standard DIN 18183 + DIN 4103
Thickness 75, 100, 125
Permitted heights 3000–5000
2750–4250
Variants CW 50/75 CW 75/100 CW 100/125
Fire protection F-30-A/EI
Sound insulation RW,R 40–47

Products

Products in this system

58206

For connecting panelling materials for sheet metal thicknesses of up to 0.7 mm with double lead thread with increased corrosion resistance requirements.

58205

For connecting panelling materials for sheet metal thicknesses of up to 0.7 mm with double lead thread with increased corrosion resistance requirements.

59011

Application area: stand profile for walls/wall faces or support profile for free-spanning ceilings with increased corrosion resistance requirements. H cut-out at each end, continuously every 250 mm and subsequently every 500 mm.

59016

Application area: stand profile for walls/wall faces or support profile for free-spanning ceilings with increased corrosion resistance requirements. H cut-out at each end, continuously every 250 mm and subsequently every 500 mm.

59015

Application area: stand profile for walls/wall faces or support profile for free-spanning ceilings with increased corrosion resistance requirements. H cut-out at each end, continuously every 250 mm and subsequently every 500 mm.

59033

Application area: supporting bracket for walls/wall faces or for free-spanning ceilings with increased corrosion resistance requirements.

59030

Application area: supporting bracket for walls/wall faces or for free-spanning ceilings with increased corrosion resistance requirements.

59034

Application area: supporting bracket for walls/wall faces or for free-spanning ceilings with increased corrosion resistance requirements.

6194

Application area: connection sealing strips, self-gluing one side for ceiling constructions. Building material class B2.

6195

Application area: connection sealing strips, self-gluing one side for ceiling constructions. Building material class B2.

6196

Application area: connection sealing strips, self-gluing one side for ceiling constructions. Building material class B2.