System no..: PW310

Double stud wall, two-layer planking

Wall system according to DIN 18183 + DIN 4103

General remarks

  •  Stiffening profiles, filler profiles for edges, junctions and terminations etc. as required.
  • When planking the substructure with other cladding materials, e.g. gypsum fiber boards, special fire protection boards, chipboards, etc., the technical data and processing guidelines of the respective manufacturer must be observed! 
  • Especially sanitary support stands for wall-hung WC and bidet must be fixed to reinforced stand profiles (U-bracing profiles including connection angle and screw connection) on both sides according to ATV DIN18340 (edition 2006). 

Specifications

Standard DIN 18183 + DIN 4103
Thickness ≥ 160, ≥ 210
Permitted heights 4500-6000 mm
4500-6000 mm
Variants CW 50 + 50/≥ 160 CW 75 + 75/≥ 210
Fire protection F 30-A/EI 30 & F 90-A/EI 90
Sound insulation RW,R 54

Products

Products in this system

5215

Application area: stand profile for walls/wall faces or support profile for free-spanning ceilings. H cut-out at each end, continuously every 250 mm and subsequently every 500 mm.

5211

Application area: stand profile for walls/wall faces or support profile for free-spanning ceilings. H cut-out at each end, continuously every 250 mm and subsequently every 500 mm.

5230

Application area: connection profile for walls/wall faces or for free-spanning ceilings.

5216

Application area: stand profile for walls/wall faces or support profile for free-spanning ceilings. H cut-out at each end, continuously every 250 mm and subsequently every 500 mm.

5234

Application area: connection profile for walls/wall faces or for free-spanning ceilings.

5233

Application area: connection profile for walls/wall faces or for free-spanning ceilings.

6187

Application area: connection sealing strips for self-gluing one side of dividing walls. Building material class B3.

6189

Application area: connection sealing strips for self-gluing one side of dividing walls. Building material class B3.

6194

Application area: connection sealing strips, self-gluing one side for ceiling constructions. Building material class B2.

6196

Application area: connection sealing strips, self-gluing one side for ceiling constructions. Building material class B2.

6248

For installing UW profiles with a drilling diameter of 6 mm. Max. mounting thickness of 12 mm. Not suitable for suspended ceilings!