System no..: PW300

Double stud wall, two-layer planking

Wall system according to DIN 18183 + DIN 4103

General remarks

  •   Stiffening profiles, filler profiles for edges, junctions and terminations etc. as required.
  •   When planking the substructure with other cladding materials, e.g. gypsum fiber boards, special fire protection boards, chipboards, etc., the technical data and processing guidelines of the respective manufacturer must be observed! 

Specifications

Standard DIN 18183 + DIN 4103
Thickness 155, 205, 255
Permitted heights 4500-6500 mm
4000-6000 mm
Variants CW 50 + 50/155 CW 75 + 75/205 CW 100 + 100/255
Fire protection F 60-A/EI 60 F 90-A/EI 90
Sound insulation RW,R 57-63

Products

Products in this system

5215

Application area: stand profile for walls/wall faces or support profile for free-spanning ceilings. H cut-out at each end, continuously every 250 mm and subsequently every 500 mm.

5211

Application area: stand profile for walls/wall faces or support profile for free-spanning ceilings. H cut-out at each end, continuously every 250 mm and subsequently every 500 mm.

5216

Application area: stand profile for walls/wall faces or support profile for free-spanning ceilings. H cut-out at each end, continuously every 250 mm and subsequently every 500 mm.

5234

Application area: connection profile for walls/wall faces or for free-spanning ceilings.

5233

Application area: connection profile for walls/wall faces or for free-spanning ceilings.

6187

Application area: connection sealing strips for self-gluing one side of dividing walls. Building material class B3.

6189

Application area: connection sealing strips for self-gluing one side of dividing walls. Building material class B3.

6188

Application area: connection sealing strips for self-gluing one side of dividing walls. Building material class B3.

6194

Application area: connection sealing strips, self-gluing one side for ceiling constructions. Building material class B2.

6195

Application area: connection sealing strips, self-gluing one side for ceiling constructions. Building material class B2.

6196

Application area: connection sealing strips, self-gluing one side for ceiling constructions. Building material class B2.