System no..: PW230

Single stud wall, single-layer planking

Wall system according to DIN 18183 + DIN 4103

General remarks

  • When planking the substructure with other cladding materials, e.g. gypsum fiber boards, special fire protection boards, chipboards, etc., the technical data and processing guidelines of the respective manufacturer must be observed! 

Specifications

Standard DIN 18183 + DIN 4103
Thickness 100
Permitted heights 4500 mm
3500 mm
Variants CW 75/100
Fire protection F 30-AB
Sound insulation RW,R ~ 40

Products

Products in this system

3762

Application area: walls/wall facings as a coverage profile in connection with hat profile no. 5143. 10 white, 22 grey

5143

Application area: walls/wall facings for attaching construction panels as a clamp system or as a mounting rail for nut/spring clips.

5215

Application area: stand profile for walls/wall faces or support profile for free-spanning ceilings. H cut-out at each end, continuously every 250 mm and subsequently every 500 mm.

5230

Application area: connection profile for walls/wall faces or for free-spanning ceilings.

5233

Application area: connection profile for walls/wall faces or for free-spanning ceilings.

6188

Application area: connection sealing strips for self-gluing one side of dividing walls. Building material class B3.

6248

For installing UW profiles with a drilling diameter of 6 mm. Max. mounting thickness of 12 mm. Not suitable for suspended ceilings!

6578

Application area: walls/wall facings as a coverage profile in connection with hat profile no. 5143.