System no..: PW220

Single stud wall, three-layer planking

Wall system according to DIN 18183 + DIN 4103

General remarks

  •  Stiffening profiles, filler profiles for edges, junctions and terminations etc. as required.
  •  When planking the substructure with other cladding materials, e.g. gypsum fiber boards, special fire protection boards, chipboards, etc., the technical data and processing guidelines of the respective manufacturer must be observed! 

Specifications

Standard DIN 18183 + DIN 4103
Thickness 175, 200
Permitted heights 8000–9000 mm
7500–8000 mm
Variants CW 100/175 CW 125/200
Fire protection F 90-A/EI 90
Sound insulation RW,R 58

Products

Products in this system

5216

Application area: stand profile for walls/wall faces or support profile for free-spanning ceilings. H cut-out at each end, continuously every 250 mm and subsequently every 500 mm.

5234

Application area: connection profile for walls/wall faces or for free-spanning ceilings.

5241

Application area: connection profile for vaulted ceilings as well as horizontal convex and concave connections to walls/columns.

5248

Application area: connection profile for walls/ wall faces or for free-spanning ceilings.

6187

Application area: connection sealing strips for self-gluing one side of dividing walls. Building material class B3.

6189

Application area: connection sealing strips for self-gluing one side of dividing walls. Building material class B3.

6188

Application area: connection sealing strips for self-gluing one side of dividing walls. Building material class B3.

6194

Application area: connection sealing strips, self-gluing one side for ceiling constructions. Building material class B2.

6195

Application area: connection sealing strips, self-gluing one side for ceiling constructions. Building material class B2.

6196

Application area: connection sealing strips, self-gluing one side for ceiling constructions. Building material class B2.

6248

For installing UW profiles with a drilling diameter of 6 mm. Max. mounting thickness of 12 mm. Not suitable for suspended ceilings!